Page 70 - 捷運技術 第35期
P. 70

62  Tomonori Umebayashi  Toshinori Kimura  Hiroyuki Morimoto  陳立島  CRASHWORTHINESS ANALYSIS OF CK371




                                       δ=0mm        δ=50mm      δ=100mm      δ=150mm



                                       δ=200mm      δ=250mm     δ=300mm      δ=350mm
                                                       Deformation (model 1e)
                                     2400
                                     2000          model 1e
                                     1600
                                    Force  [KN]  1200 800
                                     400
                                      0  0  50   100  150   200  250  300   350  400
                                                         Displacement [mm]

                                     0.5 0.4  model 1e

                                    Energy [MJ]  0.3 0.2

                                     0.1
                                     0 0   50   100   150  200   250  300  350   400
                                                        Displacement  [mm]

                                      Fig.2-2-4 Analysis result of end fuse element

            2-2) Test result

                 The cab and non-cab end fuse elements were tested respectively to confirm their crush
            behavior. Original and crushed shape of cab end are shown in Fig. 2-2-5.











                          Original(unloaded)                                 Crushed(loaded)


                                       Fig. 2-2-5 Cab end fuse element crush test

                                                                  2,000   One Mechanical Fuse Buckling Strength(Cab End) Fc=1577.63 kN
                 Fig.2-2-6 shows that the crush deformation       1,800   One Fuse Allowable strength: 1692.25kN(=6,769kN/4)
            versus reaction force during crush test, together     1,600  Fc=1680.6kN at 240mm mean displacement
                                                                  1,400
            with the result of analysis.  Analysis and test       1,200
            results agree closely until 140 mm displacement.      Load (kN)  1,000              Test result
                                                                   800
                                                                   600                          Allowable Strength
                                                                   400             Fuse length = 240mm  Analysis result
                                                                   200
                                                                    0
                                                                     0     50    100   150   200   250   300
                                                                                    Displacement (mm)

                                                                    Fig. 2-2-6 Results of analysis and test
   65   66   67   68   69   70   71   72   73   74   75