168 林文進、彭柏志 臺北捷運板南線機電系統節能儲能方案之研究
圖 1.6 超級電容儲能系統結構圖[16]
本設備設計參數如表1.6所示。
表 1.6 SES 系統參數表[16]
Technical data
Input voltage (tolerance range
[VDC] 600 750
according to EN 50163)
Total number of double-layer
1,050 1,344
capacitors
Total Capacity [F] 103 80
Usable Energy Content [kWh] 1.7 2.5
Maximum Energy Saving Possible
[kWh/h] 50 80
Per Hour
Peak Power [MW] 1 1
Auxiliaries Supply (50 Hz) [V] 3Φ AC 400 3Φ AC 400
o
Permissible Ambient Temperature [ C] -20~+40 -20~+40
Maximum Operating Height Above
[m] 2,000 2,000
Sea Level
Dimensions of The Four Double
Cubicles (width x depth x height) [m] 1.4 x 0.7 x 2.7 1.4 x 0.7 x 2.7
- Cubicle + S1/+S2 and S3/+S4 [m] 1.2 x 0.9 x 2.7 1.2 x 0.9 x 2.7
- Cubicle + S5/+S6 and S7/+S8
Weight [t] 4 4.3